ask
ChatGPTUse this when someone asks an electrical code question (NEC 2026): receptacle spacing, GFCI and AFCI, grounding and bonding, conductor sizing, box fill, clearances, and similar. Returns a plain-English answer that names the NEC section behind each claim, each checked against the 2026 code text. Shorty shows section numbers, not code text. Rephrase follow-ups as a standalone question.
calc_ampacity_derating
ChatGPTUse this when the user needs the Ampacity derating calculator. Apply ambient-temperature and more-than-3-CCC adjustments to a base ampacity. Returns the headline result and the steps, tagged with the NEC reference 310.15. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_box_fill
ChatGPTUse this when the user needs the Box fill calculator. Compute minimum box volume per 314.16(B) from conductors, clamps, devices, and EGCs. Returns the headline result and the steps, tagged with the NEC reference 314.16(B). Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_conduit_fill
ChatGPTUse this when the user needs the Conduit fill calculator. Smallest conduit that carries N conductors of one size/type per Annex C. Returns the headline result and the steps, tagged with the NEC reference Annex C. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_dwelling_service_load
ChatGPTUse this when the user needs the Dwelling service load calculator. Article 120 standard-method service load: lighting, small-appliance, dryer, range, AC/heat, EVSE. Returns the headline result and the steps, tagged with the NEC reference Article 120. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_equipment_grounding_conductor_size
ChatGPTUse this when the user needs the Equipment grounding conductor size calculator. Look up minimum equipment grounding conductor size from OCPD rating. Returns the headline result and the steps, tagged with the NEC reference Table 250.122. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_feeder_tap_rules
ChatGPTUse this when the user needs the Feeder tap rules calculator. Check 10-ft, 25-ft, or transformer-secondary tap compliance per 240.21. Returns the headline result and the steps, tagged with the NEC reference 240.21. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_four_bend_saddle
ChatGPTUse this when the user needs the 4-bend saddle calculator. Two-offset saddle (4 bend marks) for clearing a wide obstacle. Returns the bend marks and the steps. This is trade math and cites no code section. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_grounding_electrode_conductor_size
ChatGPTUse this when the user needs the Grounding electrode conductor size calculator. Look up minimum grounding electrode conductor size with rod/concrete-encased caps. Returns the headline result and the steps, tagged with the NEC reference Table 250.66. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_motor_branch_circuit
ChatGPTUse this when the user needs the Motor branch circuit calculator. Motor branch-circuit conductor (430.22) and short-circuit OCPD (430.52). Returns the headline result and the steps, tagged with the NEC reference 430.22 + 430.52. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_motor_overload
ChatGPTUse this when the user needs the Motor overload calculator. Maximum motor running-overload setting per 430.32(A)/(C). Returns the headline result and the steps, tagged with the NEC reference 430.32. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_offset_bend
ChatGPTUse this when the user needs the Offset bend calculator. Distance between bend marks and shrink for a 2-bend offset around an obstacle. Returns the bend marks and the steps. This is trade math and cites no code section. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_solar_pv_circuit_sizing
ChatGPTUse this when the user needs the Solar PV circuit sizing calculator. PV source-circuit conductor & OCPD (690.8) and load-side 120% busbar (705.12). Returns the headline result and the steps, tagged with the NEC reference 690.8 + 705.12. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_stub_bend
ChatGPTUse this when the user needs the 90° stub calculator. First-mark distance from a back-to-back target using the standard EMT take-up. Returns the bend marks and the steps. This is trade math and cites no code section. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_three_bend_saddle
ChatGPTUse this when the user needs the 3-bend saddle calculator. Center-bend mark and outer marks for a 45°/22.5° saddle over an obstacle. Returns the bend marks and the steps. This is trade math and cites no code section. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_transformer_overcurrent_protection
ChatGPTUse this when the user needs the Transformer overcurrent protection calculator. Maximum primary/secondary transformer OCPD per 450.5. Returns the headline result and the steps, tagged with the NEC reference 450.5. Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
calc_voltage_drop
ChatGPTUse this when the user needs the Voltage drop calculator. Compute single- or three-phase voltage drop and percent on a copper or aluminum branch circuit. Returns the headline result and the steps, tagged with the NEC reference Informational (210.19). Lengths are in feet or inches. If an input is missing or wrong, the error lists the fields this calculator needs.
citations_panel
ChatGPTOpens the Ask Shorty side panel that lists every NEC section Shorty cited in this conversation.
exam_check
ChatGPTChecks one exam prep answer for the Ask Shorty app.
exam_questions
ChatGPTReturns practice questions or a chapter test for the Ask Shorty app.
open_shorty
ChatGPTOpens the Ask Shorty app with field calculators and NEC exam prep. Use it when someone wants to browse calculators or practice for the exam.
settings_read
ChatGPTReads the user's Ask Shorty settings.
settings_update
ChatGPTSaves the user's Ask Shorty settings.