adverse_event_scorecard
ChatGPTUse when the user asks what goes wrong with a type of device, about complaint or failure trends, about MAUDE reports for a product code, or whether a device is safe. Report counts are not rates and cannot establish whether a device is safe. Summarise FDA MAUDE medical device reports for one product code: report counts (all-time and trailing 12 months), event-type, reporter and source mix, reporting lag, field completeness, quarterly series with spikes, top device and patient problem codes, and recalls checked. Describes the public reporting record only; report counts are not incidence rates and say nothing on their own about a device's safety.
estimate_quote
ChatGPTUse when the user asks what a prototype or small batch of a part would cost or how long it would take. Prototype Atlas. Live BUDGETARY quote band (low / likely / high USD) and lead time for a structured request. Uncalibrated model, not a supplier price; the result includes a disclaimer saying so.
find_recognized_standards
ChatGPTUse when the user asks which consensus standards apply to a device, product code or regulation, or whether FDA recognizes a standard. Search FDA's list of recognized consensus standards by product code, regulation number (e.g. 870.1130), designation (e.g. ISO 10993-1), standards body, specialty or free text. Partial recognitions are flagged with the excluded clauses. Searches a dated snapshot; the result states its date. A product code with no mapped standard does not mean the device needs none.
find_suppliers
ChatGPTUse when the user wants a shop, contract manufacturer or supplier for a part or process, near a location or overseas. Prototype Atlas. Rank suppliers for a request by fit, cost, lead time and distance. Prefers local sourcing by default and always includes at least one lower-cost international or near-shore option when allowed.
get_device_classification
ChatGPTUse when the user asks what class a device is, which regulation covers it, whether it is 510(k) exempt, or what a product code means. Look up an FDA product code in the openFDA classification database: device name, class, regulation number, review panel, submission type and whether it is exempt or third-party eligible.
get_supplier
ChatGPTUse when the user wants more about one supplier from a find_suppliers result. Prototype Atlas. Full public listing for one supplier by id: capabilities, materials, location, listed certifications, published contact routes and source URL.
list_categories
ChatGPTUse when the user asks what kinds of parts or processes can be quoted, or before quoting if the process is unclear. Prototype Atlas. List the prototype process categories (machining, laser tube cutting, extrusion, catheter builds, PCB, molding...) with their materials and typical lead-time bands. Returns the valid category ids for the quote and supplier tools.
maude_dedup_slice
ChatGPTUse first for MAUDE questions about the product codes it covers, including whether such a device is safe. It separates duplicate reports from distinct events; report counts are not rates and cannot establish whether a device is safe. Deduplicated FDA MAUDE adverse-event data for the product codes 10xAnd has processed (DQO, EOB, LIT, LRC, OWO). Returns reports vs estimated distinct events, the duplicate rate, quarterly raw and deduplicated counts, which report spikes survive deduplication and which vanish, and the top device-problem and event-type codes. Without a product_code it returns the list of covered codes. Other product codes are covered live, without deduplication, by the MAUDE scorecard. Counts are not rates and say nothing on their own about safety.
parse_request
ChatGPTUse when the user describes a part in words and the process, material or quantity needs pinning down before a quote. Prototype Atlas. Turn a free-text part description (and optional file name) into a structured request: best-guess category, alternatives, material, quantity, size, tolerance class and urgency. Deterministic keyword parse - review and correct fields before quoting.
parse_udi
ChatGPTUse when the user pastes a UDI or barcode string and wants the device identifier, lot, serial or dates, or wants to know if it is valid. Parse a GS1 or HIBCC Unique Device Identifier string (human-readable or raw barcode data): device identifier, lot, serial, expiry and manufacture dates, with a GTIN check-digit and date audit. Optionally looks the DI up in FDA GUDID.
plan_accelerated_aging
ChatGPTUse when the user asks how long to age packaging or a device in a chamber to support a shelf-life claim, or about ASTM F1980, Q10 or pull schedules. ASTM F1980 accelerated aging calculator for sterile barrier packaging and devices. From the target shelf life, the real-time storage temperature, the aging chamber temperature and Q10 (default 2.0), returns the accelerated aging factor, the chamber days needed, days saved, a pull schedule with interim and final pulls (n = 30 per pull, ISO 11607-1 test endpoints), and the standard's temperature and Q10 cautions. An engineering planning model: real-time aging must run concurrently. Relay the alerts and the disclosure.
plan_device_demo
ChatGPTUse when the user wants a product demo video or animation of a device moving through anatomy, or asks how to show where a catheter, scope or implant goes. Plans an illustrative animation of a device travelling through schematic anatomy, for a product demo video. From a description of the route ("femoral access up the aorta to the LAD") or a template id (coronary-femoral, coronary-radial, transseptal, upper-gi, bronchoscopy), returns the landmarks the device passes, the schematic lumen diameter at each, the route length, the narrowest point, and a scale check of the device diameter against it (catches mm/inch export mistakes). The video itself is rendered in their browser at the returned view_url from their STEP, STL, OBJ or GLB file; the file never leaves their machine. Anatomy is schematic, not patient data, and the animation is not a depiction of clinical performance; relay the disclosure. Remind the user that promotional video must stay within the cleared or approved indications.
plan_device_program
ChatGPTUse when the user describes a device idea and asks what it takes to bring it to market: FDA pathway, class, timeline, budget or test plan. Development roadmap for a medical device from its name and a short description: the likely FDA pathway and risk class with the reasoning, a suggested product code to check, the program phases with month ranges, total program length as a range, a cost range per work stream, the verification, biocompatibility (ISO 10993) and sterilization standards to plan for, and the US submission approach. The pathway comes from keyword matching on the description, so confirm it with get_device_classification and search_510k_clearances on the suggested product code. Month and cost ranges are planning ranges from published industry benchmarks, not quotes; the accelerated track is a 10xAnd design target, not a track record. Relay the disclosure.
quote_bom
ChatGPTUse when the user shares a BOM, parts list or assembly and wants it costed or sourced line by line. Source a whole medical device assembly from its bill of materials. For each line: whether it is purchased or custom-made and by what process, a budgetary cost band and lead time for a PROTOTYPE build and for a PRODUCTION run, and a short list of suppliers; plus a per-assembly roll-up, the line that sets the lead time, and suppliers that can make several of the custom parts. Pass either bom_text (the BOM pasted as CSV or copied Excel cells, header row first) or lines (your reading of an attached BOM, drawing package or assembly model: one object per line). Purchased parts are not priced; they get distributor search links. Every band is an uncalibrated model estimate unless the line says it is calibrated with n: the result includes a disclaimer, the assumptions and each line's flags. Firm quotes are available at the view_url.
quote_from_drawing
ChatGPTUse when the user attaches a drawing, CAD export or part photo and asks for a price, cost or lead time. Turn an engineering drawing, CAD export or part photo into a Prototype Atlas budgetary cost and lead-time band. Takes what an attached drawing specifies: process category (from list_categories), material, quantity, tightest tolerance, largest dimension, finish and documentation needs, plus a one-paragraph description. The file itself is not downloaded or stored by this tool; only its name and type are used. The result is an uncalibrated model estimate, not a supplier price, and includes a disclaimer and review flags. Firm quotes from vetted suppliers are available at the view_url.
quote_logistics
ChatGPTUse when the user asks about shipping options or what 10xAnd charges to source a part. Prototype Atlas. Shipping options and the 10xAnd fee, broken into lines like a delivery app: service fee $50, express fee (+$25 expedite, +$50 rush or same-day/flight), multi-shop fee (+$25 per extra shop), capped at $100. Parts and delivery are passed through at cost.
search_510k_clearances
ChatGPTUse when the user wants predicate devices, a competitor's clearances, or the 510(k) history of a product code, company or device type. Search FDA 510(k) premarket notifications on openFDA by 510(k) number (K123456), three-letter product code, device name or applicant. Newest decisions first. Returns the total match count, the records fetched, the exact openFDA query URL and the data date. Useful for predicate research.
search_maude_by_device
ChatGPTUse when the user names a device brand or manufacturer and asks about its adverse-event reports, without knowing the product code. Search FDA MAUDE medical device reports by device brand name or manufacturer name (phrase match), for when you do not know the product code. Returns the total report count, the product codes, brands, manufacturers and event types those reports fall under, and the newest reports. Pass a product code from the result to adverse_event_scorecard for the full picture. Report counts are not incidence rates.
select_sterilization_method
ChatGPTUse when the user asks how to sterilize a device, compares EtO, gamma, e-beam, steam or VHP, or asks which sterilization validation standard applies. Rank the 8 terminal sterilization modalities (EtO, Gamma, E-Beam, X-Ray, Steam, VHP, NO2, Dry Heat) for a device from its heat tolerance, radiation and moisture sensitivity, lumen geometry, packaging density, electronics, optics, drug or biologic content, single use vs reusable and turnaround need. Returns each modality's 0-100 fit score and status (recommended / viable / contraindicated) with the reasons, the recommended sterile barrier packaging, and the validation standards (ISO 11135, 11137, 17665, 14937, 22441, 11607). Start from an archetype (catheter, knee_implant, surgical_forceps, prefilled_syringe, camera_head, wound_hydrogel) and override any field, or pass every field. This is an engineering decision framework, not a validation or a safety determination: relay the disclosure.
suggest_materials
ChatGPTUse when the user asks which material to use for a part or how a material choice changes cost. Prototype Atlas. Material options for a category with their notes and effect on the budgetary quote, cheapest first.